Home> Products> Air Cooler Turbine> Evaporative condenser of air cooling system
Evaporative condenser of air cooling system
Evaporative condenser of air cooling system
Evaporative condenser of air cooling system

Evaporative condenser of air cooling system

Payment Type:T/T

Incoterm:FOB,CFR,CIF,EXW

Min. Order:1 Set/Sets

Transportation:Ocean

Port:Shanghai

Product Description
Product Attributes

Model No.Air cooler

Place Of OriginChina

Tube Bundle Type"GP6X1.95-6-98.2-1.21S-17.32/DR-VIa"

Tube Bundle MaterialSA179 K01200

Fin MaterialAL 1060

Motor ModelYB3-160M1-8 380V, 50HZ

Frame TypeGJP6×1.95B-15/3F

Air Cooler Structurehorizontal placement

Fan ModelG-TF15L4-Z4

Supply Ability & Additional Information

PackagingModules are shipped in bulk/packaged

TransportationOcean

PortShanghai

Payment TypeT/T

IncotermFOB,CFR,CIF,EXW

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Modules are shipped in bulk/packaged

Evaporative condenser of air cooling system



Product introduction


The use efficiency of air cooler depends on a number of factors, including indoor and outdoor temperature, humidity, air flow, energy efficiency ratio of air conditioning equipment, etc. Generally speaking, the higher the air temperature, the greater the humidity, the worse the air circulation, the lower the efficiency of the air cooler will be. Air Cooler Turbine,Industrial Air Cooler,Greenhouse Air Cooler,Cooling System Evaporative Air Cooler In addition, air conditioning equipment with high energy efficiency ratio can reduce energy consumption more effectively and improve the use efficiency. Therefore, when selecting an air cooler, select the appropriate equipment based on the actual situation and use it properly, for example, cleaning the air filter regularly and maintaining indoor ventilation.


Air Cooler 2



Product parameter

Air cooler structure: horizontal placement

Tube bundle type: "GP6X1.95-6-98.2-1.21S-17.32/DR-VIa"

Tube bundle material: SA179 K01200

Fin material: AL 1060

Fan model: G-TF15L4-Z4

Motor model: YB3-160M1-8 380V, 50HZ

Frame type: GJP6×1.95B-15/3F






Note:

1. The medium, temperature and pressure in the pipe should meet the design conditions, and overpressure and overtemperature operation is strictly prohibited;

2, the pipe pressure, temperature, should be slowly step by step, so as not to damage the equipment due to impact heat;

3, the air cooler normal operation, should first open the fan, and then to the tube bundle into the medium, stop the operation, should first stop to the tube bundle into the medium, then stop the fan;

4, the negative pressure operation of the air cooler boot, should first open the air extractor, tube to reach the specified vacuum degree and then start the fan, and then through the tube medium, shut down, according to the opposite procedure, winter operation, open the air extractor, to reach the specified vacuum degree, first through the tube medium, then start the fan, so as not to freeze the tube can not run;

5. When stopping, low pressure steam should be used to purge and clean the condensate to avoid freezing and corrosion.





Hot Products
Home> Products> Air Cooler Turbine> Evaporative condenser of air cooling system
Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send